3 0 obj <> <> These cookies ensure basic functionalities and security features of the website, anonymously. Im new to the forum, Im currently completing the level 3 2365 G&G with just the Design unit to finish. Particular attention should be given to the following points: 2.1.1 The gun shall be attached securely to the cable using lead packing where the cable is Stockton-On-Tees WebCourse Overview. After C.A.T deactivate transmitter button OFF14. Est. <> endobj 4 0 obj So regulation 722.531.3.1 says RCD's shall disconnect all live conductors. Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet. male spade (see Figure 3). You also have the option to opt-out of these cookies. This cookie is set by GDPR Cookie Consent plugin. WebAuthorised Person shall, by the use of an Approved Spiking Procedure at the point of work, identify the cable to be worked on and then prove it dead. WebWith our high voltage cable spiking and identification training course, youll learn to perform cable spiking with appropriate equipment and also how to identify different types of Portable grounding devices shall be secured to permanently grounded objects at the location B. Cable spiking is part of a procedure to positively identify the cable to be worked on at the point of work, which may be a joint hole in the ground somewhere along the cable route. XnZ?d$%q* {LhL`J{rDG2)3J9+0#eT ,X|N FO"9iGujO2"b#cooszz| 6 O\/_X~qq{8@p$}T~?f>tLsW od'xK After you spike the cable the amplitude of the signal diminishes significantly downstream of the spiking gun. Video - BSI Kitemark Anyone attending training should also have a good level of both spoken and written English. Cable spiking is an essential part of proving that high voltage cables are completely dead this training course is an effective method for learning about the principles behind cable spiking, as well as how to safely perform spiking. We have received your request and will respond promptly. So for example a clean unfaulted HV cable between two open switches would tyically have a resistance of several megohms or even giga ohms to earth or between phases, but after spiking this would drop to Ohms rather than megohms. WebTrain to be an authorised person responsible for limited switching operations in high voltage environments with our City and Guilds accredited training programme. The specification details the required skills, knowledge and PASS Ltd are a City and Guilds accredited training provider, specialising in electrical training, including 18th edition, PAT testing, electrical installer courses and other training courses including thermography, Part P and solar panel installation. Just thought it might interest some of the domestic lads on here who may never have seen it before. They are going off and back on but not tripping at the fuse box. Substation Earth End Clamps Substation Line End Clamps, Substation Earthing LeadsSubstation Operating PolesSubstation Operating SocketsSubstation Earthing SpigotsSubstation Fixed EarthingEarth Tape Repair KitsSubstation Discharge Rods, Transmission Earth End Clamps Transmission Line End Clamps, Transmission Sparrow Plate Transmission Tee Connectors, Transmission Earthing LeadsTransmission Running EarthTransmission Operating SocketTransmission Operating PolesTransmission Deas Bar, Distribution Earth End Clamps Distribution Line End Clamps Distribution Cross Arms Clamps, Distribution Operating Sockets Distribution Fuse Heads Distribution Pole Adaptor Heads, Distribution Operating Poles Distribution Carrying Bag, Distribution Aluflex LeadsDistribution Cluster Bars and Terminal PlatesDistribution Earth Rods and NestsDistribution Earthing Kits, Rail Shorting Bonds Rail Continuity Jumper Kit, Rail DEP Short EarthRail J117 ClampsRail Long Blue Interlocked EarthRail Short Circuiting StrapsRail Operating Pole KitRail Voltage DetectorsRail Sockets and HeadsArboriculture EquipmentRail Signal Sighting Target, M-TAG Voltage Detector H-TAG Voltage Detector, Beacon Voltage DetectorDS/MS/VA Voltage DetectorWD/6B/DE Voltage DetectorWestminster Discharge RodsMD Proving UnitV Check Proving UnitD3 Live Line IndicatorALADIN Personal AlarmLink Box Earthing Kits, Personal Protection EquipmentElectrical SafetyInsulated ToolsTemporary ProtectionSignage and MarkingLocking OutBags and CabinetEmergency Equipment, MV Cable ToolsLV Cable ToolsSpare Cable ToolsPower Cable cutting & Spiking Tool, Home Power Cable Spiking and Cutting Tools. Open tool. Delegates who fail or do not wish to undertake the competence assessments will receive a Faraday Training Group attendance certificate. %PDF-1.5 5nV{,_B goh'(D"rlB'B5TX`4TR}l;-iji-ZplpnYB1q=yYeEI$2Zb&JR\!ySi`nBLz/*+BI K>3zj+BtX9S;ZiV+YAu4X*R-La0eXT*8P= GD2teP.1v. DSR 5.9.2 and CP606 B02 - 1.2/3.0 An approved spiking procedure shall be used to ]uq!no'1BTF^,#aT23;=?R8Y>kzyTx|>=i@D*z`}%yn 2.8 Using a hammer and pliers lift the point of the arrow. What is this black tarry stuff on the cable? Admin #2 Posted : 23 October 2008 12:51:00(UTC) Rank: However, you may visit "Cookie Settings" to provide a controlled consent. Ive scoured the forum for a My daughter lives in a flat in London in converted circa 1900 5 storey terrace in Bethnal Green. endobj Electrical News from Electricians Forums and Friends, Changing 2 gang light switch to smart dimmer, Require URGENT HELP regarding compex 01 & 04 re-sit. The lineman, at a distance of 35 feet, pulls the lanyard, removing the Book now by choosing your programme date. The G670 has a Spike transformer. Install Earthing Braid & Rod3. For a better experience, please enable JavaScript in your browser before proceeding. Design, installation, construction, commissioning, energising, maintaining and operating high voltage electrical infrastructures on 11kV, 33kV and 132kV private networks. This cookie is set by GDPR Cookie Consent plugin. endobj This course is not a cable fault location course. As part of this training progamme, youll be taught by our professional high voltage tutors and be provided a practical, technical and safety-oriented introduction to both identifying electrical power cables and the correct process of performing cable spiking on these cables. 1.3 In Electricity North West there are five Approved Spiking Procedures for identifying a high voltage cable: a) Injected Signal b) Elimination of all other cables c) Visual tracing We also provide full HV electrical testing services for HV pressure testing up to 68kV and sheath and cable They were taken on site in my last job for my apprentices log book. Discuss Cable spiking in the Commercial Electrical Advice area at ElectriciansForums.net, Reply to Cable spiking in the Commercial Electrical Advice area at ElectriciansForums.net, This official sponsor may provide discounts to registered members. Webd) Spike the cable. Click Here to join Eng-Tips and talk with other members! Position the cable vertically so that it is centered between the apparatus bushing and parking pocket, parallel to, and 6.00 inches (152.0 mm) from the apparatus front plate WIth the greatest of respect I would have thought that if you have to ask for one then competency in this area is questionable. For more information call us on 01642 987 978 or email [email protected] for more information Programme Details Course Details b)M0d'_MtBQe3. Electric power & transmission & distribution Forum, Low-Volume Rapid Injection Molding With 3D Printed Molds, Industry Perspective: Education and Metal 3D Printing. I am looking for some advice. WebAn approved spiking procedure shall be used to identify the cable. There are a limited number of facilities globally that can safely conduct a cable spike test on medium voltage owing to the significant power demands drawn from the national grid and the violent effects of the test. 2.7 At the point where the two tool cuts join, use the edge of a six inch half round file to deepen the cut until the underlying papers JavaScript is disabled. It's a similar thing with LV cables but there may be other cables jointed to the cable or connected loads which diminish the resistance to start with. WebDamage to underground electrical cables can cause fatal or severe injury and the law says you must take precautions to avoid danger. Turn button on Zero. 1 0 obj Cable spiking is part of a procedure to positively identify the cable to be worked on at the point of work, which may be a joint hole in the ground This in particular cable is a 4core 75mm, and it was providing a supply for a DB In the utility industry in the UK it is usual to strip and test LV cables rather than spiking them, but most of the jointing is done live to avoid customer interruptions. Delegates who successfully complete the course and both theoretical and practical assessments will receive a Faraday Training Group competence certificate. With a heritage spanning over eighty years, and world-class experience in equipment designed for the safe maintenance of power systems, PBwel provides customers with high-quality service, reliable solutions and technical expertise. $^4qm/ Ol,$HF:;K0Lz!11y-~i.k +XCBeIG #QJH {2Fh6Hq#@ ? We also use third-party cookies that help us analyze and understand how you use this website. Examine how the principles of DfAM upend many of the long-standing rules around manufacturability - allowing engineers and designers to place a parts function at the center of their design considerations. Please carefully consider any advice you receive. 7r*T;5.vO!:R2buhqT`:;|]s$I4Vu3IuLQERwW' }|l@88p Regards Marmite. Any help much appreciated. There are three types of connection for the high voltage cable: Spike, Rajah, and 6.35 mm (1/4 in.) A faulted cable might show a low resistance to ground due to a fault. WebSpiking is used to ensure that the cable is not live. We have the test capability to identify and locate cable faults for systems up to 33kV, For more information about our range of high voltage electrical services or to discuss a particular project, please call us on +44 (0)7739 592307 or email: [email protected], Call us today or send us an email to get free consultation. We also provide full HV electrical testing services for HV pressure testing up to 68kV and sheath and cable fault identification. 3 0 obj Login. The before/after insulation resistance values of a spiked cable will depend on shielding/grounding. When creating a high voltage line by connecting high voltage cables, it is difficult to keep the cables connected by simply linking them together, as described above. Postings made by forum users are personal opinions. \D 0eiTQe stream 1 0 obj 2 0 obj The Dual cables were for redundancy, not voltage drop. The purpose of spiking a cable is the last test to prove its dead and safe to work on. This method is better when you have more than one cable in the ground as it helps you to provisionally ID the cable prior to spiking. idle or abandoned cables that are not part of a network, as Circuit Main Earths cannot be applied. Put safety mat7. The SPIKE Tool is a safety device used to keep electrical workers safe. Im going to install a hard wired 230v security camera, incorporating floodlights, outside and above garage door onto brick. I don't suppose there is an example any of you could draw on that I could use for my technical question in my examination? A division of, High Voltage Cable Spiking & Cable Identification Course (City & Guilds Accredited), C&G 2365 Electrical Installations (Level 2), C&G 2365 Electrical Installations (Level 3), C&G 2365 Electrical Installations (Combined), C&G 2391-50 Initial Verification (Level 3), C&G 2391-51 Periodic Inspection (Level 3), C&G 2391 Initial/Periodic Inspection (Combined), C&G 2392-10 Fundamentals & Initial Verification, LCL Domestic Electric Installer (DEI-Part P), C&G 2921-31 EVSE Charging Point Installer (Level 3), High Voltage Authorised Person (SAP) / Switching, Authorised Person Limited Operation of HV Systems, Authorised Person Limited Operation of HV Systems (Refresher), HV Sanction for Test Receipt Authorisation, Practical Intro to Safe Operation of Switchgear (15kV), Safe Operation of 33kV HV Systems (33kV Upgrade), Senior Authorised Person Safe Switching Operation of HV Systems, C&G Wind Turbine SAP Safe Switching of Power Distribution Networks, Safe Access to HV Substations & Switchrooms, C&G Earth Electrode Testing on HV Systems, C&G Dielectric Strength Testing (Pressure Testing), Authorised Person Safe Operation of HV Systems, Senior Authorised Person Safe Switching of HV Systems, Safe Use of Electrical Equipment in Hazardous Areas, C&G HV Cable Spiking & Cable Identification, High Voltage Onsite Training & Consultancy, ITC Thermal Camera (Thermography) Training Level 1, ITC Thermal Camera (Thermography) Training Level 2, ITC Thermal Camera (Thermography) Training Level 3, Online ITC Foundation Thermography Course, Online ITC Level 1 Thermal Camera (Thermography), Authorised Person Boiler & Pressure Systems, Authorised Person Boilers & Pressure Systems Course (Refresher). E$H"3/xcI #7h z5P$#Nx?9ih(C8#ZfR SpU`Q9d'8v: M> pWl '*z*"nTNiM4W91Qq} O95B)HpSn*1fA%WcSc-cL}Sk-)`K ~cb1l,@! P2}FqI_VG5WPStJ*1Jzdo:N(;PDawAo,nA$gm50]G9da+Yoo4JQrh-AS0)1-l25QO_A$_)EJRW6mW*k|1K3>/`$G4Y15)K\_bdJ+@7A't.q,[Qr=cqp+H9Xq<8|E8I\4Zo$L_((o#kI%its/b^wr +"Wz;tea^GWk`t;2zFAvhTsdF\`K;+(Y|V3X"c. *\F)[oNO&&fg6@qeR 1 Alberto Street The cookie is used to store the user consent for the cookies in the category "Other. xYYo~7O Xn85;dA0-3$S& STU_}utKw? Analytical cookies are used to understand how visitors interact with the website. SPIKE pierces the neutral or sheath of a cable, as well as its insulation, to reach the main conductor. TS18 2BQ, You can view more info on the training centre by visiting this link >>. Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors. 1. Where new cables arejointed to existing cables the test requirements are modified asdescribed in this SWP to cater for the aged insulation of existingcables. There are a number of great reasons why choosing to take an electrical training course in the summer is cool. <>/Font<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 612 792] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>> The garage has a ring of sockets Hope one of you had a firearms certificate. 4 0 obj WebThis bulletin includes basic procedures for performing an at battery rescue charge on high voltage (HV) Ni-MH and Li-ion batteries. I#V@C)AOVp(Rz*kP)dfcxF7PYX$JBa1"9 document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Unit 1, Leafield Way, Leafield Ind. We follow stringent current health and safety procedures in all aspects of this work. for the electricity generation and transmission, electricity distribution, rail and electric mobility and traction industry. This course is designed for personnel who have previous authorisation up to 15kV, who wish to extend their authorisation level to enable them to operate on (indoor) 33kV systems. Close this window and log in. Learn methods and guidelines for using stereolithography (SLA) 3D printed molds in the injection molding process to lower costs and lead time. Good pics! Copyright 1998-2023 engineering.com, Inc. All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission. It simulates the accidental "spiking" of a live cable installation and ensures that the circuit protection will operate and the circuit fails to safety - for example if a mechanical digger accidentally pierces cable that is buried direct in the ground whilst it is doing groundwork. endobj c) The consent of the Technical Authority / Duty Holder must be obtained prior to spiking. The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. Go back. Already a Member? e) Call Control and ask if any alarms have been received. This course takes place in Stockton-on-Tees in North East England at our high voltage training centre. WebHigh Voltage Cable Spiking & Cable Identification Course (City & Guilds Accredited) Duration 1 Day Course Type Practical & Theory Award Competency Certificate Examination Written Ref CP 606 B02 - 1.2/1.3 If the visual tracing method is to be used, the cable to be identified shall be visually traced The cookies is used to store the user consent for the cookies in the category "Necessary". Book now by choosing your programme date. How to check if 3 phase is easily available for a flat ? David, Welcome Guest! <>>> These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc. Swalek provide specialist engineering teams to carry out cable spiking on underground cables. <>>> In case there is no procedure described in the instruction manual, never remove the cover and do not touch the inside of the power supply. stream STAFFING Posted By JJ Est. Wait until the operation is complete (roughly 2 to 5 min) 13. The cookie is used to store the user consent for the cookies in the category "Analytics". Necessary cookies are absolutely essential for the website to function properly. &#O.qZ^ (b#un, 2 Genesis Business Park These cookies track visitors across websites and collect information to provide customized ads. WebSpike Testing for cables is designed to prove that a cable with a wire screen is capable of withstanding the maximum designated voltage in the event of a sudden surge in current. {: (s % It is deemed a destructive Type test - as you will see from the footage, this is a single instance test and it renders the cable unusable afterwards. x[[s~NM g:q.mkNi>dDIN] @$dFb@7{y^z>T%KJb9 /v- {Kv~;TU^ p~mY{Pg"M_p32)t"OtC4QP9rz_Sn/?|lgl5Wl90 0x1b8j|4r> A96,|zlB?v1=R0~LJ'NpX&$/2,%+7Losvd"&(A{xgp-%[u8\V4nFOnD#(lsm*T Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. Install the Picoup5. At 13,800 Volts, the nominal operating voltage, one amp 3 phase is 20,000 watts, so 20KW per amp.